Installation – Waterford Appliances T25-LP User Manual

Page 8

Advertising
background image

8

Waterford TARA T25 Direct Vent Freestanding Gas Stove

INSTALLATION

9) Connect the red wire from the thermodisc to the red wire of

the speed control wire harness.

10) Connect the live black wire from power cord to the black wire

of the speed control wire harness.

12) Ensure all wires are pulled away from firebox to avoid excessive

heat and secure with stick-on wire clip.

13) Re-attach rear access panel with 6 screws, reversing step 7.

NOTE: Pull excess wire next to fan to avoid excessive heat

from the firebox.

11) Slide the thermodisc into the bracket clip on the underside of the

firebox.

NOTE: When power cord is plugged in, speed control is in the
ON position and stove is burning, allow 10 - 15 minutes for
the thermodisc (temperature switch) to activate and turn on
the Fan automatically.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug.

Advertising