Installation, Wiring diagram - tara, Optional remote control – Waterford Appliances T25-LP User Manual

Page 28: Final check

Advertising
background image

28

Waterford TARA T25 Direct Vent Freestanding Gas Stove

WIRING DIAGRAM - TARA

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat
will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. If any of the original wires as supplied with
the appliance must be replaced, it must be replaced with CSA type SEW-2 (200

o

C) or its equivalent.

INSTALLATION

OPTIONAL REMOTE

CONTROL

Use the Waterford Remote Control Kits ap-
proved for this unit. Use of other systems may
void your warranty.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect firing rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to

ensure that the flame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.

Thermostat Wire Table

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall to

install the receiver and the receptacle box
(protection from extreme heat is very im-
portant). Run wires from the fireplace to
that location, use Thermostat Wire Table.

2) Connect the wires as per the wiring dia-

gram below.

CAUTION

Do not connect the millivolt remote

control wires to the 120V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring er-
rors can cause improper and
dangerous operation.