Installation, Optional front grill, Removing the cast iron front panel – Waterford Appliances T25-LP User Manual

Page 26: Aeration adjustment

Advertising
background image

26

Waterford TARA T25 Direct Vent Freestanding Gas Stove

OPTIONAL

FRONT GRILL

1) Remove the Cast Iron Front Panel. Catch the

cast iron front panel at the bottom and lift
upwards and out from the stove. Once free
of the locating tabs, the panel can be dropped
down; freeing it from the top of the stove.

Place the cast iron front panel on a non-
abrasive surface, away from any traffic to
ensure that it does not get damaged.

2) Lay the grill into position on the inside of the

Cast Iron Front Panel and secure using the
2 screws provided.

REMOVING

THE CAST IRON

FRONT PANEL

1) Hold the cast iron front panel at the bottom

and lift upwards and out from the stove.
Once free of the locating tabs, the panel can
be dropped down; freeing it from the top of
the stove.

Place the cast iron front panel on a non-
abrasive surface, away from any traffic to
ensure that it does not get damaged.

2) Remove the Front Glass Panel. Using a 7/16"

socket wrench, remove the 6 hex head
bolts used to secure the glass panel and
frame to the stove. Remove the frame and
glass panel and set it aside.

Securing the

Cast Iron Front Panel

1) Catch the panel in the viewing area and on

the bottom edge.

2) Place the front panel against the stove just

below the top panel.

3) Slide the panel upwards under the top

panel. When the top is in position, push the
bottom edge into position. Push downwards
to secure the locating pins in the locating
tabs.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply, air
supply or altitude. The flames should not extend
to the top of the firebox and excessive soot
should not be present. The air shutter and the
flue restrictor setting will both affect the flame
pattern.

Natural Gas:

1/4" (7mm) open

Propane:

wide open

1) Remove the Front Cast Iron Panel and Glass

Panel, see instructions on page 26.

2) Remove the complete log set. (See Log

Installation instructions on page 27).

3) Using a 1/4" nut driver or flat screwdriver,

loosen the locking screw on the burner air
shutter.

INSTALLATION

8) Using the 1/4" nut driver or flat screwdriv-

er, tighten the locking screw on the burner
air shutter.

9) Replace the log set, glass panel and Cast

Iron Front Panel.

Caution: Carbon will be produced if the
air shutter is closed too much.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT cov-
ered under warranty.

Note: Aeration Adjustment should only

be performed by an authorized
Regency Installer at the time of
installation or service.

4) Replace the log set, and glass panel.

5) Insert a 3/16" Allen wrench into the adjust-

ing key (through) the hole on the rear panel
of the stove).

6) Turn the mechanism until to change the

flame pattern. Turning clockwise will dimin-
ish the flame, and turning counter-clock-
wise will increase the flame. The rear flame
must not extend and touch the top of the
firebox and no soot should be forming on
any surfaces.

7) Remove the glass panel, and the log set.