99

-

Oxygen partial pressure display: 0.5 - 1.6 bar depending on the limit setting.

-

Oxygen Limit Fraction: 1 - 200% with 1% resolution

Logbook/Dive Profi le Memory:

Recording interval: 20 seconds adjustable (1-10-20-30-60s), records the maximum
depth, minimum temperature and minimum tank pressure of each interval.

-

Memory capacity: approximately 36 hours of diving with 20 seconds recording
interval.

-

Depth accuracy: 0.3 m [1 ft].

Operating Conditions

-

Normal altitude range: 0 to 3000 m [10000 ft] above sea level.

-

Operating temperature: 0°C to 40°C [32°F to 104°F].

-

Storage temperature: -20°C to +50°C [-4°F to +122°F].

It is recommended that the instrument be stored in a dry place at room temperature.

NOTE! Do not leave the dive computer in direct sunlight!

Tissue Calculation Model

-

Suunto Deepstop RGBM algorithm (developed by SUUNTO and Bruce R.
Wienke, BS, MS and PhD).

-

9 tissue compartments.

-

Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minu-
tes (on gassing). The off gassing halftimes are slowed down.