SUUNTO D9 User Manual

Page 78

Advertising
background image

76

Continuous beeps and activated backlight when:

-

the maximum allowed ascent rate, 10 m/min [33 ft/min], is exceeded. Ascent
rate bar graph blinks and STOP warning appears (Fig. 6.6.).

-

the decompression ceiling depth is exceeded. An error warning Er and a
downward pointing arrow appear. You should immediately descend to, or be-
low, the ceiling. The instrument will otherwise enter a permanent Error Mode
within three minutes, indicated by a permanent Er (Fig. 6.13.).

You are able to preset alarms before the actual dive. The user programmable alarms
can be set for maximum depth, dive time and time. The alarms activate when:

-

The preset maximum depth is reached
-

continuous beep series for 24 seconds

-

the maximum depth blinks as long as the present depth value exceeds the ad-
justed value.

-

The preset dive time is reached
-

continuous beep series for 24 seconds or until any button is pressed.

-

the dive time blinks for one minute

- The preset alarm time is reached

-

the current time is shown.

-

continuous beep series for 24 seconds or until any button is pressed.

-

the current time blinks for one minute