Unity 552 User’s Manual

Technical
Specifica-
tions

The following tables detail the technical specifications for the

iPump 562

.

RF Characteristics

Table 1.3: iPump 562 RF Characteristics

Contact Closure GPIO DB-9 Female

Connector Pin

Input/Output

Description

1

Alarm Common

2

Alarm Normally Open

3

Contact Closure Common

4

No Connection

5

Input

Contact Closure GPIO Input

(Factory use only)

6

Alarm Normally Closed

7

Contact Closure Normally Closed

8

Contact Closure Normally Open

9

NA

Ground

Power DC IN 12 V 5 A

Connector

Input/Output

Description

Standard IEC

Input

115 or 230 V AC

External Input/Output Interfaces

RF Characteristics

RF Input

Connector Type F

Input Frequency Range

950 - 2150 MHz

Input Level Range

-25 to -65dBm

Maximum Aggregate Input Power

-8 dBm at max input signal

Input Impedance

75 ohms

Input VSWR

< 2.5:1

Input Noise Figure

8 dB MAX at minimum input level

L.O. Leakage at Input

< -55 dBm

Demodulator

DVB-S QPSK

DVB-S2 QPSK

DVB-S2, 8PSK

FEC Rate 1/2, 2/3, 3/4, 5/6, or 7/8 (1.0 to 45 MBaud) ½, 2/3,
¾, 4/5, 5/6, 7/8, 9/10 (2 to 30 MBaud) 2/3, ¾, 5/6, 8/9, 9/10
(3 to 30 MBaud) Convert Symbol Rate Fs to Transport Rate
Ft by: (2R*Fs)*(188/204)=Ft, where 'R' is inner FEC code
ratio, either R=1/2, 2/3, 3/4, 5/6, or 7/8.

Max Symbol-rate

S2 = 30 Msps; S1 = 45 Mbps