Waterford E61 Gas Fireplace Insert

INSTALLATION

VENTING

THE APPLIANCE MUST NOT BE CON-
NECTED TO A CHIMNEY FLUE SERV-
ING A SEPARATE SOLID FUEL BURN-
ING APPLIANCE.

This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. The flue length must
be a minimum length of 8' (2.44m) and a maxi-
mum of 35' (10.7m). See chart for minimum
distances from roof. Periodically check that the
vent is unrestricted.

Masonry chimneys may take various contours
which the flexible liner will accommodate. How-
ever, keep the flexible liner as straight as
possible
, avoid unnecessary bending.

HIGH ELEVATION

This unit is approved in Canada (CAN/CGA-
2.17-M91) for altitudes to 2000 ft. (610m) using
the factory -installed burner orifice. For instal-
lations from 2000 ft (610m) to 4500 ft (1370m)
the orifice sizes (DMS) for the Natural Gas and
Propane units must be changed. See the rating
plate for details. For installations above 4500 ft.
refer to current ANSI Z223.1 Sc8-8.1.2a ap-
pendix F or CAN/CGA-B149.1, for resizing
orifice.

GAS CONNECTION

The Emerald Insert is factory equipped to burn
Natural Gas, if necessary the unit can be
converted to burn Propane by using Conver-
sion Kit # 260-960. For minimum and maximum
supply pressure see the System Data table on
page 8.

Note: Prior to any pressure testing of

the gas supply piping system that
exceeds test pressures of 1/2
psig, this appliance and its individ-
ual shut-off valve must be discon-
nected from the piping system. If
test pressures equal to or less
than 1/2 psig are used then this
appliance must be isolated from
the piping system by closing its
individual manual shut-off valve
during the testing.

GAS CONNECTION WARNING:

Only persons licensed to work with gas piping
may make the necessary gas connections to
this appliance.

1) The gas inlet is located on the end of the

flexible pipe that emerges from the lower
left rear corner of the unit. The inlet fitting is
a 1/2" female flare.

A separate gas shut-off valve and a 1/8" IPS
plugged tapping should be installed immedi-
ately upstream of the connection to the
appliance.

2) The gas inlet is located on the end of the

flexible pipe that emerges from the lower
left rear corner of the unit. The inlet fitting is
a 1/2" female flare.

A separate gas shut-off valve and a 1/8" IPS
plugged tapping should be installed immedi-
ately upstream of the connection to the
appliance.

3) Locate the center point where the vent will

pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.

4) The gas control valve is provided with two

"IN" and "OUT" pressure taps, and are
easily accessible for a test gauge connec-
tion (see diagram on page 12).

5) Once the gas has been connected ensure

that the pilot valve is in line with burner.

CAUTION: If the door is removed or
opened for servicing, it must be replaced
and closed prior to operating the appli-
ance. The glass must be fixed in the door
when operating.

Recommended Gas Pipe Diameter

Pipe Schedule 40 Tubing,
Length Pipe Type L
(feet) Inside Diameter Outside Diameter

NG

LP

NG

LP

0 - 10

1/2"

3/8"

1/2"

3/8"

1.3cm 1.0cm

1.3cm 1.0cm

10 - 40

1/2"

1/2"

5/8"

1/2"

1.3cm 1.3cm

1.6cm 1.3cm

40 - 100

1/2"

1/2"

3/4"

1/2"

1.3cm 1.3cm

2.0cm 1.3cm

100 - 150

3/4"

1/2"

7/8"

3/4"

2.0cm 1.3cm

2.3cm 2.0cm

Note: Never use plastic pipe. Check to confirm
whether your local codes allow copper tubing
or galvanized pipe.

System Data:

E61 Converted to

27,000 (Natural Gas)

or 29,000 (Propane)

For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:

Natural Gas Propane
Burner

#40

#52

Max. Input Rating

- Natural Gas

27,000 Btu/h

- Propane

29,000 Btu/h

Min. Input Rating

- Natural Gas

13,500 Btu/h

- Propane

14,500 Btu/h

Output Capacity with blower Off

Natural Gas

21,168 Btu/h

Propane

23,258 Btu/h

Output Capacity with blower On

Natural Gas

21,708 Btu/h

Propane

23,925 Btu/h

Supply Pressure

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

Manifold Pressure

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

System Data

For 0 to 2000 feet altitude

Burner Inlet Orifice Sizes:
Natural Gas Propane

Burner

#32

#50

Max. Input

- Natural Gas

38,000 Btu/h

- Propane

35,000 Btu/h

Min. Input

- Natural Gas

19,000 Btu/h

- Propane

17,500 Btu/h

Max. Output Capacity with blower On

Natural Gas

30,666 Btu/h

Propane

28,700 Btu/h

Supply Pressure:

Nat. Gas

min. 5" w.c. (1.25 kPa)

Propane

min. 12" w.c. (3.0 kPa)

Manifold Pressure

Natural Gas 3.8" +/- 0.2" w.c. (0.94 kPa)
Propane

11" +/- 0.2" w.c. (2.7 kPa)

System Data - HIGH ELEVATION

For 2,000 - 4,500 feet altitude

Burner Inlet Orifice Sizes:

Natural Gas
Burner

#33

Max. Input

.

- Natural Gas

36,100 Btu/h

Advertising
This manual is related to the following products: