Waterford E61 Gas Fireplace Insert

CONVERSION KIT

FROM NATURAL GAS

TO PROPANE MODEL

#260-960

for Emerald E61 Gas Insert

using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE

DONE BY A QUALIFIED

GAS FITTER

IF IN DOUBT DO NOT DO THIS

CONVERSION !!

Conversion Kit Contains:

Qty. Part #

Description

1

910-018 SIT Conversion Kit-50%

Turndown LP

1

910-383 LP Injector (Pilot Orifice)

1

904-641 Burner Orifice #50

1

908-455 Decal "Converted to Propane"

1

908-528 Red "PROPANE" label

1

908-173 Instruction Sheet

1) Shut off the gas supply.

2) Open the lower grill and remove the 2

screws holding the control panel in place.

Remove the 2 screws holding the

Control Panel in place.

FLUE LINER

INSTALLATION

1) Cut the flex liner as required.

2) Mark the end of one liner to indicate

Inlet.

3) Connect the other end of the above liner to

the inlet side of the termination adaptor, seal
connection with high temperature silicone.
Secure with gear clamp.

4) Connect the 2nd liner to the exhaust side of

the adaptor, seal connection with high tem-
perature silicone. Secure with gear clamp.

5) Install flashing.

6) Insert both liners into chimney, passing

through the damper opening.

7) Install termination cap.

8) Connect the marked end of the liner to

the inlet collar of the vent connector plate
marked with an "I", seal connection with
high temperature silicone. Secure with
gear clamp.

9) Connect the 2nd liner to the exhaust collar

marked with an "E", seal connection with
high temperature silicone. Secure with
gear clamp.

Part #

Description

948-305

3" Flex - 35 ft.

946-529

Co-linear DV Vertical
Termination Cap

Alternate Approved Caps
980

Vertical Termination Cap

991

High Wind Cap

923GK

3" Co-linear Adaptor with flashing

In areas on consistently high winds, we recom-
mend using the Simpson Dura-Vent System
(923GK adapter and 991 high-wind cap).

The Air Intake pipe must be attached to the inlet
air collar of the termination cap.

INSTALLATION

NOTE:

1) Final gas connection should be made

after unit is in place to avoid damage to
line when pushing the unit into position.

2) Mill-pac may be used instead of high

temperature silicone and screws may
be used instead of gear clamps at con-

nections of liner to inlet and vent col-
lars.

10) Attach the top shield to the top front lip of

the firebox using 3 screws.