Effective output scan rate selection, Digital output signal polarity selection, Overall checksum selection – Welch Allyn SCANTEAM 3400PDF User Manual

Page 43

Advertising
background image

3–3

SCANTEAM 3400PDF User’s Guide

Effective Output Scan Rate Selection

60 inches per sec.

120 inches per sec.

This sets the transmission rate of the Digital Output Signal. The available

parameters assume a bar code density of .010 inches (10 mil).

15 inches per sec.

30 inches per sec.

Digital Output Signal Polarity Selection

This programming parameter allows you to set the output logic convention for

the digitaloutput. The choices are White High (Laser Output) and Black High.

Default = Black High.

Black High

White High

Overall Checksum Selection

When enabled, a computed check character will be added at the end of the

entire message.

The check character is the character which when

ExclusiveĆORed with every preceding character of the message yields a result

of 0x00 (00H). Default = Disable.

Enable

Disable