8–2

SCANTEAM 3400PDF User’s Guide

Replacing the Interface Cable

The standard interface cable is attached to the scanner with an 8-pin modular

connector. When properly seated, the connector is held in the scanner handle

by a flexible retention tab. The cable's designed to be field replaceable.

Notes:

Order replacement cables from Welch Allyn or from an authorized

distributor.

When ordering a replacement cable, specify the cable part number of the

original interface cable.

Turn the power to the host system OFF.

To Replace the Interface Cable:

Disconnect the scanner cable from the terminal or computer.

Locate the small hole on the side of the scanner handle near the

base (see Figure below).

Straighten one end of a paper clip.

Insert the end of the paper

clip into the small hole and

press in. This depresses

the retention tab, releasing

the connector. Pull the

connector out of the

scanner

handle

while

maintaining pressure on

the paper clip.

Replace with the new cable.

Insert the connector into the opening at the base of the scanner

handle. Press firmly. The connector is keyed" to go in only one

way, and will clickinto place.

Cable

Release

To Reset Factory Settings

If you aren't sure what programming options have been set up in your

scanner, or you've changed some options and now want the factory

settings restored, refer to Main Menu Selections in Section 1 and scan

the Factory Default Settings bar code.