Wybron Transition Optic User Manual

Page 11

Advertising
background image

11

Maximum ambient temperature (t

a

) may not exceed 40˚C (104˚F)

Keep objects at least 2” (50mm) from sides of the fixture.
Keep objects at least 6” from the top of the fixture.

Cabinet or Closet Mounting

The Transition may be mounted in a closet or cabinet on a hard
surface such as wood, laminate, or metal.

Do not mount the Transition on soft surfaces such as linoleum or
fabric.

Maximum ambient temperature (t

a

) may not exceed 40˚C (104˚F)

Keep objects at least 2” (50mm) from sides of the fixture.
Keep objects at least 6” from the top of the fixture.

Pipe mounting

The Transition may be pipe mounted using the optional pipe mount

bracket. See diagram for acceptable pipe mounting orientations.

Connecting Fiber Common End

Connecting fiber to the illuminator is as simple as inserting the fiber
common end into the mounting port and tightening the set screw.

The Transition CMY Fiber Illuminator works with fiber common end
bundles with clear apertures ranging from 17 – 32mm diameter. The
mounting port is interchangeable to match the type of fiber bundle ferrule
being used. Consult the factory regarding the correct mounting port to be

used in your application.

Connecting AC Power

CAUTION: Be sure the fixture is properly grounded.

The user should ensure that a good source of AC power is available that
complies with local building and electrical codes and has both overload

and ground fault protection. Use only 18/3, type IEC power cord.

Input power must be 110 – 240VAC, 50/60Hz.

Advertising