Cleaning the Color Filters

It is recommended that the color filters be only cleaned with low-pressure

air without disassembling the color filters from the motor shafts. If the
color module must be disassembled to clean the dichroic filters take
careful note of the location and offset height of the individual color flags.
Color filters must be reassembled in exactly the same orientation
and correct heights to ensure proper operation!

CAUTION:

Dichroic filters are easy to break! Support the glass from
the behind when cleaning the surface.

Remove cover.

Remove 4 screws holding color filter plate into Transition chassis.

Holding glass hex rod, slide the motor plate back toward the reflector

and then up out of the chassis after it is clear of the rod.

Noting filter location and height loosen hub setscrew and slide filter

and hub from motor shaft.

Reverse previous operation to reassemble color module

Cleaning the hex integration rod

Initialize unit, command flags to open white positions, and power

down.

Allow unit to cool.

Disconnect fiber bundle from output port

Remove cover

Clean rod sides and ends with window cleaner

Reassemble cover, and fiber bundle.