Specifications

MODEL LWO-112 (Oil)

Input rating ......................................................................................................................................140,000 BTU/HR
Nozzle ..............................................................................................................................................1.0 G.P.H. - 80 H
Burner ........................................................................................................................................Wayne Model - MSR

MODEL LWG-112 (Gas)

Input rating.........................................................................................................................................140,000 BTU/HR
Output rating .....................................................................................................................................112,000 BTU/HR

NAT LP

Orifice .......................................................................................7/32" (.218 dia.)

9 (.136 dia.)

Manifold Pressure .....................................................................3.5 W.C.P

11.0 W.C.P.

Burner.............................................................................................................................Wayne Model P250-AF-DI-Y

MODEL LWO-112 or LWG-112

Blower Size (Belt Drive) ................................................................................................................................10" x 10"
Blower C.F.M ............................................................................................................................................. 800 - 1800
Motor Size ........................................................................................................................................1/3 - 1/2 - 3/4 HP
Firebrick Lined..........................................................................................................(7) 9” x 6” x 2” • (8) 12” x 6” x 2”
Cast Iron Grates - Standard .......................................................................................................................(3) 16” x 8”
Wood Fire Door .............................................................................................................................................11" x 10"
Air Filter................................................................................................................................................. 20" x 25" x 1"
Wood Combustion Chamber Size ................................................................................................................ 24" x 16"

MODEL LWO-168 (Oil)

Input rating.........................................................................................................................................189,000 BTU/HR
Output rating.....................................................................................................................................151,000 BTU/HR
Nozzle ..............................................................................................................................................1.35 G.P.H - 80 H
Burner ........................................................................................................................................ Wayne Model - MSR

MODEL LWO-168 (Gas)

Input rating.........................................................................................................................................189,000 BTU/HR
Output rating.....................................................................................................................................151,000 BTU/HR

NAT LP

Orifice ......................................................................................“F" (.257 dia.)

“23” (.154 dia.)

Manifold Pressure .....................................................................3.5 W.C.P

11.0 W.C.P.

Burner.............................................................................................................................Wayne Model P250-AF-DI-Y

MODELS LWO-168, or LWG-168

Blower Size (Belt Drive).................................................................................................................................11" x 10"
Blower C.F.M ............................................................................................................................................1200 - 2000
Motor Size ........................................................................................................................................1/3 - 1/2 - 3/4 HP
Firebrick ................................................................................(10) 9” x 6” x 2” • (7) 12” x 6” x 2” • (1) 9” x 4-1/2” x 2”

Cast Iron Grates - Standard .......................................................................................................................(3) 18” x 8”
Wood Fire Door................................................................................................................................ 13-1/4" x 13-1/4"
Air Filter..................................................................................................................................................20" x 25" x 1"
Wood Combustion Chamber Size .................................................................................................................24" x 18"

NOTE: It is recommended that a 2", non combustible, raised pad be used for the furnace.

This will prevent moisture from getting under the furnace and causing corrosion.