General ................................................................................ 1

Inspection............................................................................. 1

Reference............................................................................. 1

Approvals ............................................................................. 1

Nomenclature....................................................................... 2

INSTALLATION

Limitations ............................................................................ 3

Location ............................................................................... 3

Rigging and Handling .......................................................... 3

Clearances........................................................................... 3

Ductwork .............................................................................. 3

Fixed Outdoor Air Intake Damper ........................................ 4

Condensate Drain ................................................................ 4

Compressors........................................................................ 4

Filters ................................................................................... 4

Service Access .................................................................... 4

Thermostat........................................................................... 4

Power and Control Wiring .................................................... 4

Optional Electric Heaters ..................................................... 5

Optional Economizer/Mot. Damper Rain Hood ................... 5

Optional Power Exhaust Rain Hood .................................... 7

OPERATION

Cooling System.................................................................. 15

Preliminary Operation Cooling........................................... 15

Cooling Sequence of Operation......................................... 15

Heating Sequence of Operation ........................................ 15

Heat Anticipator Setpoints ................................................. 16

Checking Supply Air CFM.................................................. 16

Defrost Sequence of Operation ......................................... 17

Secure Owner’s Approval .................................................. 18

MAINTENANCE

Normal Maintenance ......................................................... 18

TABLES

No. Description Page

1

Unit Application Data ..................................

3

2

Control Wire Sizes ......................................

5

3

Electric Heat Application Data ....................

5

4

Physical Data ..............................................

8

5

Four and Six Point Loads............................

10

6

Supply Air Blower Perf. 15 Ton....................

12

7

Supply Air Blower Perf. 20 Ton....................

12

8

Static Resistances ......................................

13

9

Power Exhaust Performance ......................

13

10

Blower Motor and Drive Data......................

13

11

Electrical Data (Basic Units) .......................

14

12

Electrical Data (Units w/Elec. Heat)............

14

13

Heat Anticipator Setpoints ..........................

16

FIGURES

No. Description Page

1

Typical Rigging............................................

3

2

Center of Gravity.........................................

3

3

Fixed Outdoor Air Damper..........................

4

4

Recommended Drain Piping.......................

4

5

Typical Field Wiring .....................................

5

6

Adjusting Enthalpy Setpoint........................

7

7

Dimensions and Clearances.......................

9

8

Four and Six Point Loads............................

10

9

Belt Adjustment...........................................

16

10

Pressure Drop versus Supply Air CFM ......

16

11

Defrost Initiation Times ...............................

17

12

Ambient Modified Time/Temp. Control ........

18

TABLE OF CONTENTS

B

1

C

H

E

C

1

E

PRODUCT NOMENCLATURE

PRODUCT GENERATION

1 = 1st Generation

PRODUCT CATEGORY

B = Single Package Heat Pump
(Air Cooled)

PRODUCT IDENTIFIER

CH = Heat Pump

VOLTAGE CODE

25 = 208/230-3-60
46 = 460-3-60
58 = 575-3-60

NOMINAL HEATING

CAPACITY

180 = 15 Tons
240 = 20 Tons

FACTORY INSTALLED

OPTION CODE

EC = Sing. Input Economizer
DK = Diff. Input Economizer
FD = Sing. Input Economizer
w/Power Exhaust
CF = Diff. Input Economizer
w/Power Exhaust
BG = Motor Outdoor Air
Damper

0

8

8

1

0

2

5

FACTORY INSTALLED

HEAT

A = No Heat
E = Electric

NOMINAL COOLING

CAPACITY

018 = 18 KW

036 = 36 KW

054 = 54 KW

072 = 72 KW

511.06-N3Y