background image

NOTE: If this hood replaces another one, please note that the location of the air exhaust

can vary from one manufacturer to another.

5. INSTALL THE ADAPTER/DAMPER

Fold down the foldable flange (C) of the
adapter/damper. This flange must be at 90°
from the remaining flanges. Use the lower
screw holes on each side of the
adapter/damper to assemble it to the back
of hood. See below.

- 6 -

It may be necessary to adjust the
adapter/damper location to the existing wall
discharge opening. Leave the foldable
flange (C) of the adapter/damper as is. Use
the upper screw holes on each side of the
adapter/damper to assemble it to the back
of hood. See below.

H

ORIZONTAL DISCHARGE

,

NEW INSTALLATION

H

ORIZONTAL DISCHARGE

,

HOOD REPLACEMENT

4. PREPARE THE HOOD

Remove both filters from the hood.
Disassemble the adaptor/damper (A) from the
hood.

NOTE: The adapter/damper is located inside

the hood. Remove the bottom panel
(B) to access the adapter/damper.
Refer to figure beside.

HO0093

A

B

Punch out the electrical and discharge knock-outs for the chosen opening (vertical on top or
horizontal at the back of the hood). Refer to figure below.

HD0219

V

ERTICAL

D

ISCHARGE

H

ORIZONTAL

D

ISCHARGE

HJ0008

C

HJ0009

C

Advertising