Reinstall bottom panel and filters, Connect wiring – Zephyr ES1-E30AB User Manual

Page 8

Advertising
background image

- 8 -

8. REINSTALL BOTTOM PANEL AND FILTERS

Reinstall the bottom panel, using the
retaining screw previously removed in
step 4 plus 4 others from parts bag.
Refer to illustration beside.

Then, reinstall filters.

HO0097

WARNING

Risk of electrical shock. Electrical wiring must be done by qualified
personnel in accordance with all applicable codes and standards. Before
connecting wires, switch power off at service panel and lock service
disconnecting means to prevent power to be switched on accidentally.

!

7. CONNECT WIRING

Connect cable to range hood wiring
using included wire connectors.

Connect BLACK to BLACK, WHITE to
WHITE and GREEN or BARE WIRE to
GREEN ground screw (1).

HE0059

WARNING

Do not forget to connect the ground!

!

1

Advertising
This manual is related to the following products: