6. INSTALL THE HOOD

Run power cable to installation
location. Place the hood at its
location. Using a pen, mark the
position of the screws (smaller part
of the embossed

keyholes).

Remove the hood and install four
1/2” double thread screws at sides
locations (A), leaving a 1/8” gap.
Place the wire clamp, insert the
cable in the hood and tighten the
wire clamp to secure the cable.
Place the hood under the cabinet
and slide it in position. Make sure
the adapter/damper assembly
enters the ducting and the damper
opens freely. Secure the hood by
tightening the screws completely.
Install the last 1/2 double thread
screw (B) in the remaining
embossed hole.

HD0218

NOTES:

1. For the best ventilation performance, if a round duct must be used, the duct

diameter must be 6” or more. Use a 3¼” x 10” to 6” round transition.

2. The wall duct must be well prepared to receive the adapter. Before performing

the installation, make sure the adapter fits easily in the duct.

A

LL INSTALLATIONS

Using two 1/2” screws, secure the
adapter/damper to the top or back of the
hood. Tape the adapter/damper to the hood
using duct tape to seal it.

HO0095

5. INSTALL THE ADAPTER/DAMPER

(CONT’D)

For a vertical discharge installation only,
leave the foldable flange (C) of the
adapter/damper as is. This flange must be
located towards the front of the hood.
See beside.

HO0096

C

V

ERTICAL DISCHARGE