The electrical connection should be made

using a double pole isolating switch (cooker

socket) with at least 3mm contact separation

in all poles. The cable must have

conductors of sufficiently high cross-

sectional area to prevent overheating and

deterioration.

The recommended cross-section area is six

square millimetres (6.00mm

2

).

The cable should be routed away from

potentially hot areas marked by X. See

Fig.1.

To move the appliance, open the oven door,

and lift the appliance by holding inside the

top of the compartment. See Fig.2.

This is a type Y appliance, which means it is

free-standing and can be fitted with cabinets

on one or both sides. It may also be fitted in

a corner setting.

Side walls which are above hob level should

be protected by heat resistant non-

combustible material and MUST NOT be

nearer than 40mm to the hob side.

A nominal air gap of 2mm at either side of

the appliance is required to enable the

appliance to be moved into position.

Always ensure an air gap is maintained at

hotplate level. Tiles or other forms of deep

wall covering should not obscure this gap.

See Fig.3.

Overhanging surfaces or a cooker hood

should be a minimum of 685mm above the

hob. See Fig.4.

It is important to ensure that the appliance is

level after installation. Levelling feet are

fitted to the appliance to accommodate

uneven floors.