INSTALLATION INSTRUCTIONS

12

Clearance Heights

The cooker hood is designed to be fitted over a
cooking appliance at the clearance heights stated,
providing the maximum output of the appliance
beneath does not exceed the maximums quoted in
the Technical Specifications.

If the output of the appliance below the cooker hood
exceeds the maximum outputs quoted, please refer
to the cooker manufacturer’s installation instructions.

A minimum clearance height of 650mm(25 1/2 ”) is
required when installed above a built-in electric hob,
or 700mm (27 1/2 ”) when installed above a built-in
gas hob.

A minimum clearance height of 685mm (27”) is
required when installed above a slot-in electric oven,
or 787mm (30 1/2 ”) when installed above a slot-in
gas oven.

When installed between adjoining wall cabinets, the
wall cabinets must not overhang the hob and the
distance between the underside of the cabinet and
the worktop must be 450mm. If the height of the wall
cabinet is less than 450mm a gap of 50mm must be
maintained either side of the hob.

This cooker hood must not be installed
above a cooking appliance with a high level
grill.

This appliance can be used in either a ducting or
filtering mode.
Ducting – Cooking vapours and/or odours are passed
straight outside (ceiling and/or wall) via a disposal
duct, using the holes that are on the top and/or the
back of the appliance.
Filtering – Cooking vapours and/or odours are
removed from the air by 2 charcoal filters and the air
is then re-circulated around the room from the front
vents.
ATTENTION: For the filtering option it is absolutely
necessary to use the charcoal filters but not for the
ducting option.

A: Built-in Electric Hob:

650mm minimum clearance

B: Built-in Gas hob:

700mm minimum clearance

C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker:

787mm minimum clearance