Periodic maintenance and adjustment – Yamaha VMX17Y(C) User Manual

Page 84

Advertising
background image

PERIODIC MAINTENANCE AND ADJUSTMENT

7-33

1

2

3

4

5

6

7

8

9

8. Pull the battery out of its compart-

ment.

To charge the battery

Have a Yamaha dealer charge the bat-
tery as soon as possible if it seems to
have discharged. Keep in mind that the
battery tends to discharge more quickly
if the vehicle is equipped with optional
electrical accessories.

NOTICE

ECA16520

To charge a VRLA (Valve Regulated
Lead Acid) battery, a special (con-
stant-voltage) battery charger is re-
quired. Using a conventional battery

charger will damage the battery. If
you do not have access to a con-
stant-voltage battery charger, have a

Yamaha dealer charge your battery.

To store the battery

1. If the vehicle will not be used for

more than one month, remove the
battery, fully charge it, and then
place it in a cool, dry place.

NOTICE:

When removing the

battery, be sure the key is
turned to “OFF”, then discon-
nect the negative lead before
disconnecting the positive
lead.

[ECA16302]

2. If the battery will be stored for more

than two months, check it at least
once a month and fully charge it if
necessary.

To install the battery

TIP

Be sure the battery is fully charged.

1. Place the battery in its compart-

ment.

2. Fold the heat insulator back to its

original position.

NOTICE:

Make

sure that the heat insulator is in
its original position and it is
properly folded.

[ECA16550]

3. Install the rubber damper.
4. Install the battery cover (together

with the ECU) by installing the
bolts.

5. Connect coupler A.
6. Install the main fuse (together with

the holding band) on its holder.

7. Connect the positive battery lead

first, then connect the negative
battery lead by installing their bolt.

1. Heat insulator
2. Battery

1

2

1. Heat insulator

1

Advertising