Zenith P60W26 User Manual

Page 51

Advertising
background image

51

Safety instructions

Monitor Overview

Connections

Basic operation

Sleep timer

Picture & Sound

Others

Special features

Communication Parameters

Command Reference List

-

The RS-232C input jack is used to control the Monitor’s functions using an external control device.

Baud rate : 2400 bps (UART)

Data length : 8 bits

Parity : None

Stop bit : 1 bit

Communication code : ASCII code

* If the command interval is interrupted for more than 4

seconds, only Command 1 will be recognized.
Be careful when using the power command.

Transmission

* [Command] : To control PDP set.
* [Set ID]

: You can adjust the set ID to choose

desired monitor ID number in special
menu. See page 50. Adjustment range
is 1 ~ 99.
When selecting Set ID ‘0’, every connected
PDP set is controlled.

* [DATA]

: To transmit command data.

Transmit ‘FF’ data to read status of
command.

* [Cr]

: Carriage Return

ASCII code ‘0x0D’

* [ ]

: ASCII code ‘space (0x20)’

[Command][ ][Set ID][ ][Data][Cr]

OK Acknowledgement

* The Monitor transmits ACK (acknowledgement) based

on this format when receiving normal data. At this
time, if the data is data read mode, it indicates present
status data. If the data is data write mode, it returns
the data of the PC computer.

[Set ID][:][OK][x][Data][x]

Error Acknowledgement

* The Monitor transmits ACK (acknowledgement) based

on this format when receiving abnormal data from
non-viable functions or communication errors.

[Set ID][:][NG][x]

Transmission / Receiving Protocol

NAME

COMMAND

DATA RANGE

01. Power

p

0 ~ 1

02. Input Select

i

0 ~ 3

03. Aspect Ratio

r

0 ~ 2

04. Screen mute

m

0 ~ 1

05. Volume mute

w

0 ~ 1

06. Volume control

v

0 ~ 64

07. Contrast

k

0 ~ 64

08. Brightness

b

0 ~ 64

09. Color

c

0 ~ 64

10. Tint

t

0 ~ 64

11. Sharpness

s

0 ~ 64

12. OSD select

d

0 ~ 1

13. Abnormal state

a

0 ~ 1

14. PIP/DW

z

0 ~ 3

15. PIP input select

e

0 ~ 1

16. PIP sound select

u

0 ~ 1

17. PIP position

x

0 ~ 3

18. remote control

j

0 ~ 1

adjustment mode

Advertising