Zenith P60W26 User Manual

Page 55

Advertising
background image

55

Safety instructions

Monitor Overview

Connections

Basic operation

Sleep timer

Picture & Sound

Special features

Others

* COMPONENT source only works in 480i input signal.

16. PIP sound select (Command:u)

G

To select main or sub (inset) sound for PIP/Twin picture.

You can also select sound select in PIP/DW on the
special menu.

Transmission

[u][ ][Set ID][ ][Data][Cr]

Acknowledgement

Data 0 : Main picture sound

1 : Sub picture sound

Data 0 : Main picture sound

1 : Sub picture sound

[Set ID][:][OK][x][Data][x]

* If external equipment commands the Monitor to

"change into remote control adjustment mode", the
Monitor can only be adjusted by the remote control.
To revert the Monitor control to external control device
adjustment, turn the Monitor off and then on again.

18. Change into Remote control

adjustment mode (Command:j)

G

To control the Monitor with the remote control while
the cable is still connected.

Transmission

[j][ ][Set ID][ ][Data][Cr]

Acknowledgement

Data 0 : PC adjustment mode

1 : Remote control adjustment mode

Data 1 : Remote control adjustment mode

[Set ID][:][OK][x][Data][x]

17. PIP position (Command:x)

G

To select sub picture position for PIP.
You can also adjust the sub picture position using the
position button on the remote control or in PIP/DW on
the Special menu.

Transmission

Data 0 : Right down on screen

1 : Left down on screen
2 : Left up on screen
3 : Right up on screen

[x][ ][Set ID][ ][Data][Cr]

Acknowledgement

Data 0 : Right down on screen

1 : Left down on screen
2 : Left up on screen
3 : Right up on screen

[Set ID][:][OK][x][Data][x]