Common Printing Problems

Troubleshooting Guide

Problem

Solution or Reason

STATUS indicator

does not light GREEN

when power switch is

turned to the ON (1)

position.

1. Check power connections from the printer to

the outlet.

With the STATUS

indicator light GREEN,

the printer appears to

be working, but

nothing is printed.

1. Verify that the labels are the correct type.

2. Check the roll and verify that the print surface

faces up for (direct thermal) printing.

3. Check that the transfer ribbon is correctly

routed and has the ink side out (TLP only).

Printing is faded or

poor quality.

1. Clean the print head with cleaning pen.

2. Adjust print speed/darkness in software or

with programming.

3. Check the roll and verify that the media print

surface is facing up.

4. Verify that the correct combination thermal

transfer ribbon and media are in use.

Printing stops and the

STATUS indicator

lights RED.

1. Possible problem sensing labels with transmis-

sive (gap) sensor. Perform AutoSense adjust-

ment. Align the transmissive (gap) sensor

position, see page 22.

2. Possible problem with label media.

a) Gap between the bottom of a label and the

top of the next label should be at least 1/16".

b) For tags, see Tag Media Sensing, page 46.

c) Use only Eltron approved labels and tags.

3. Possible label jam.

4. Check that the media is correctly routed.

5. Possible software/programming problem.

a) Check the printer memory configuration.

b) Refer to the EPL2 Programming manual

for the correct data syntax.

6. Transmissive sensor is dirty. Clean media

path.

42

980181-001 Rev.C

Troubleshooting