Installa tion - in ternal blo w e r – Zephyr ATI-M90ABX User Manual

Page 11

Advertising
background image

Installa

tion - In

ternal Blo

w

e

r

6. Remove the 6” round metal knockout pla-

te from the blower plate by using a fl at
head screwdriver. See. Fig.4

7. Remove the (10 ) screws securing the blo-

wer plate to the blower housing and remo-
ve blower plate. See. Fig.5

(Note! If air is discharged from the top, do not

rotate the plate; proceed from step 10 in-
stead).

8. Remove the rectangular plate and the fi -

xing bracket from the motor plate by loo-
sening the 6 screws. Fig.6

9. Rotate the motor plate by 90° and fi x the

rectangular plate and the fi xing bracket in
the opposite direction as shown in Fig.7

10. Place the 6"

metallic fl an-
ge on the blo-
wer's air outlet
(the fl ange may already be pre-installed).
Install internal blower into blower plate
and secure using (4 ) screws included with
the blower. See Fig. 8

11. Fasten the two brackets to the sides of

the motor by fi xing them onto the motor
plate with (4 type B) screws, and to the si-
des of the motor with another (4 type C)
screws. Fig 9

12. Secure capacitor box connected to the provided cable to the blower plate

using (2 type B) screws included with the blower. See fi g. 10

- 11 -

Advertising