Installa tion - p o w er supply c onnec tion – Zephyr ATI-M90ABX User Manual

Page 19

Advertising
background image

Installa

tion - P

o

w

er Supply C

onnec

tion

GENERAL

• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations.

POWER SUPPLY CONNECTION

For connection to the power supply refer to the following:

1. Remove the power supply cover by undoing

the (2) screws Fig. 17.

2. Break through the hole on the box.
3. Pass the wires through the hole in the box and

fasten the power supply conduit. Fig.18

4. Connect the wires of the hood to those of

the power supply as described. Fig.19 :

BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground

- A double-pole switch properly rated must

be installed to provide the range hood power
supply disconnection.

- Connect the electrical conduit to the Field

Wiring Compartment using listed onduit
fi ttings.

- Carry out the power supplly connection in

accordance with the national electric code,
ANSI/NFPA 70-1999.

5. Insert the wires into the box, then close the

box cover, securing it using the screws that
were previously removed.

6. Put the Decortive Mesh Filter back on and clo-

se the front panel while holding it by its external sides until it shuts; then put
the canopy back on.

- 19 -