A user-replaceable AC power fuse (see Figure 6) is located just to the left
of the power on/off switch. For use with both voltage ranges, the
replacement fuse is a 5 x 20 fast blow style rated at 5 Amp/250 VAC.

1. Before replacing the fuse, turn the AC power switch off and unplug

the AC power cable.

2. To replace the fuse, insert the tip of a flathead screwdriver into the slot

in the end of the fuse holder end cap.

3. Press in slightly on the end cap and turn the screwdriver slightly

counterclockwise. This disengages the end cap from the fuse holder
and permits the removal of the fuse.

4. To install a new fuse, remove the old fuse and insert the new fuse into

the fuse holder.

5. Push the end cap in slightly, then insert the tip of a flat blade

screwdriver into the slot in the end cap and turn clockwise to engage it.

6. Plug in the AC power cable and turn the AC power switch on.

0HFKDQLFDO $GMXVWPHQWV

This printer has been designed so that minimal operator adjustments are
required.

3ULQW 4XDOLW\ $GMXVWPHQWV

When changing from one media/ribbon combination to another, only slight
changes in print darkness or toggle pressure may be required. For these
situations, refer to “Toggle Pressure Adjustment” on page 40.