Appendix, Rs-232 connector technical information, Interconnecting to dte devices – Zebra Technologies S400 User Manual

Page 75: Interconnecting to dce devices, L›c‹à, 56 &rqqhfwru 7hfkqlfdo ,qirupdwlrq

Advertising
background image

Zebra S400 & S600 User’s Guide

67

®®l›c‹à

56 &RQQHFWRU 7HFKQLFDO ,QIRUPDWLRQ

NOTE: When XON/XOFF handshaking is selected, data flow is
controlled by the ASCII control codes DC1 (XON) and DC3
(XOFF). The DTR control lead has no effect.

,QWHUFRQQHFWLQJ WR '7( 'HYLFHV

The printer is configured as data terminal equipment (DTE). To connect
the printer to other DTE devices (such as the serial port of a personal
computer), use an RS-232 null modem (crossover) cable. Figure 31 shows
the required cable connections.

,QWHUFRQQHFWLQJ WR '&( 'HYLFHV

When the printer is connected via its RS-232 interface to data
communication equipment (DCE) such as a modem, a STANDARD
RS-232 (straight-through) interface cable must be used. Figure 32 shows
the connections required for this cable.

RS-232 Connector Pinouts

Pin. No.

Description

1

Not used

2

RXD (receive data) input to the printer

3

TXD (transmit data) output from the printer

4

DTR (data terminal ready) output from the printer — controls when the host
may send data

5

Chassis ground

6

DSR (data set ready) input to the printer

7

RTS (request to send) output from the printer — always in the ACTIVE
condition when the printer is turned on

8

Not used

9

5 V Fused

Advertising