Battery Type

To ensure the batteries are receiving the proper charge
voltage, the Battery Type must be selected for the type of
batteries used in the system: GEL Cell, Flooded Lead Acid
and AGM. The default setting is GEL Cell.

This voltage varies depending on the batteries used, as
specified below.

Table 3-1 Battery Capacity Settings

Setting

Absorption Charge Time

Auto

110 minutes (1.8 hours)

125 A-hrs

60 minutes (1 hour)

250 A-hrs

90 minutes (1.5 hours)

375 A-hrs

120 minutes (2 hours)

500 A-hrs

150 minutes (2.5 hours)

1000 A-hrs

180 minutes (3 hours)

Figure 3-4 Battery Capacity menu items

Table 3-2 Battery Type and Charge Voltage

Battery Type

Bulk VDC

Float VDC

Equalize VDC

GEL Cell

14.1

13.6

Defeated

Flooded Lead Acid

14.6

13.4

15.5

AGM

14.4

13.4

15.5