Inverter/charger error messages, Caution – Xantrex Technology RC/GS RC7 User Manual

Page 49

Advertising
background image

System Status Displays

975-0210-01-01

37

Inverter/Charger Error Messages

Error messages appear when a fault is detected with either the
inverter or charger. The red Error LED lights, and the buzzer
sounds. Error messages for the inverter/charger display the
error condition as well as a suggested remedy.

CAUTION

Only flooded lead acid or AGM batteries should be equalize
charged. Running an equalize charge on batteries other than flooded
lead acid or AGM types could permanently damage them.

CAUTION

Do not attempt to remove vent caps on AGM batteries. Doing so
may void the warranty.

CAUTION

All DC loads should be disconnected during the equalize charge
period due to the higher voltage (more than 15 volts DC) applied to
the batteries.

Note:

The equalizing mode is defeated if GEL cell is selected as

the battery type.

Figure 4-12 Equalizing Mode

Inverter

Charge

Batt. Full

Error

822-4A-001

System Status:

Equalizing

Charge LED quickly flashes (8 times per
second). Batt Full LED is on solid.

RC-GS_manual.book Page 37 Thursday, May 26, 2005 4:58 PM