Begin gen quiet and end gen quiet (rc/gs only) – Xantrex Technology RC/GS RC7 User Manual

Page 33

Advertising
background image

Configuring the RC/GS and RC7

975-0210-01-01

21

Begin Gen Quiet and End Gen Quiet (RC/GS Only)

The period of time during which the generator is prevented
from starting automatically can be defined using the RC/GS.

To specify the begin quiet time, scroll to the Begin Gen
Quiet: 00:00 by using the Up and Down arrow buttons. Set
the Begin Gen Quiet start time. The selected digit for hours or
minutes will be underlined and highlighted (to set the time,
see “Set Clock (RC/GS Only)” on page 17).

Press the Down arrow to access the End Gen Quiet: 00:00
menu and select the appropriate end time.

Figure 3-17 Begin Generator Quiet Time display

Figure 3-18 End Generator Quiet Time display

Note:

Setting Begin Gen Quiet and End Gen Quiet to the same

time defeats the quiet time mode.

Note:

If the generator is running when quiet time begins, it shuts

down automatically. The buzzer also sounds and the screen shows
the message “Gen Quiet Fault.” If the auto-start condition still
exists at the end of quiet time, the generator will start.

Begin Gen Quiet

00:00

End Gen Quiet

00:00