Cooling capacity - with air handler coils – York YMA024 User Manual

Page 4

Advertising
background image

036-21570-002 Rev. D (0605)

4

Unitary Products Group

**

Refer to Quick Selection Chart for specific furnace match-up.

COOLING CAPACITY - With Air Handler Coils

UNIT

MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

TOTAL

CAPACITY

SENSIBLE
CAPACITY

SEER

W/O TXV

SEER

W/ TXV

EER

1 PH 12 SEER HP WITH N1AH / G2FD

YMA02411

N1AHB08

2,5,8,10 17

G2FD030(S,H)17(T)

800

24.0

18.8

12.00

12.00

10.90

N1AHB12

2,5,8,10 17

G2FD030(S,H)17(T)

800

24.0

18.8

12.00

12.00

10.90

YMA03011

N1AHB08

2,5,8,10 17

G2FD030(S,H)17(T)

1000

30.0

23.0

12.00

12.00

11.10

N1AHB12

2,5,8,10 17

G2FD030(S,H)17(T)

1000

30.0

23.0

12.00

12.00

11.10

N1AHB08

2,5,8,10 17

G2FD036(S,H)17(T)

1200

35.2

27.2

12.00

12.00

11.05

YMA03611

N1AHB12

2,5,8,10 17

G2FD036(S,H)17(T)

1200

35.2

27.2

12.00

12.00

11.05

N1AHC16

5,8,10,15,20 21

G2FD036(S,H)21(T)

1200

35.6

28.0

12.00

12.00

11.30

YMA04211

N1AHC16

5,8,10,15,20 21

G2FD048(S,H)21(T)

1400

42.0

32.8

12.00

12.00

10.70

N1AHD20

8,10,15,20,25,30

24 G2FD048(S,H)24(T)

1400

42.0

32.8

12.00

12.00

10.70

YMA04811

N1AHD20

8,10,15,20,25,30

24 G2FD060(S,H)24(T)

1600

46.0

35.6

-

12.00

10.20

N1AHD20

8,10,15,20,25,30

24 G2FD061H24 1600

46.0

36.0

-

12.00

10.25

YMA06011

N1AHD20 8,10,15,20,25,30

24

G2FD060(S,H)24(T)

1800

54.0 42.2

11.70

-

10.50

N1AHD20 8,10,15,20,25,30

24

G2FD061H24

1800

54.5 42.4

12.00

-

10.55

1 PH 12 SEER HP / N1VS - VARIABLE SPEED

YMA02411

N1VSB12

2,5,8,10 17

G2FD030(S,H)17(T)

775

24.2

18.5

13.00

13.00

11.95

YMA03011

N1VSB12

2,5,8,10 17

G2FD030(S,H)17(T)

1000

30.2

22.8

13.00

13.00

11.95

YMA03611

N1VSB12

2,5,8,10 17

G2FD036(S,H)17(T)

1200

35.4

26.8

12.50

12.50

11.65

N1VSC16

5,8,10,15,20 21

G2FD036(S,H)21(T)

1200

36.0

27.6

13.00

13.00

12.20

YMA04211

N1VSC16

5,8,10,15,20 21

G2FD048(S,H)21(T)

1380

42.5

32.4

13.00

13.00

11.45

N1VSD20

8,10,15,20,25,30

24 G2FD048(S,H)24(T)

1350

42.5

32.0

13.00

13.00

11.40

YMA04811

N1VSD20

8,10,15,20,25,30

24 G2FD060(S,H)24(T)

1600

46.0

35.0

-

12.50

10.65

N1VSD20

8,10,15,20,25,30

24 G2FD061H24

1600

46.5

35.4

-

12.50

10.70

YMA06011

N1VSD20 8,10,15,20,25,30

24

G2FD060(S,H)24

1780

53.5 40.6

12.00

-

10.65

N1VSD20 8,10,15,20,25,3

24

G2FD061H24

1780

54.5 41.4

12.10

-

10.85

1 PH 12 SEER HP / F2RP / RC / FP / FC / FV

3,4

YMA02411

F2RC/F2FC036

5,8,10,15 18

-

800 24.0

18.8 12.00

12.00

10.90

F2RP/F2FP/F3FP024

5,8,10,15 18

-

800 23.6

18.6 12.00

12.00

10.90

F2RP/F2FP/F3FP030

5,8,10,15 18

-

800 24.0

18.8 12.00

12.00

10.90

YMA03011

F2RC/F2FC036

5,8,10,15 21

-

1000 29.6

22.2 12.00

12.00

11.05

F2RP/F2FP/F3FP030

5,8,10,15 21

-

1000 29.6

22.2 12.00

12.00

11.05

F2FP/F3FP040

5,8,10,15 21

-

1200 36.0

27.2 12.00

12.00

11.30

YMA03611

F2RP/F2FP/F3FP036

5,8,10,15 21

-

1200 35.8

27.0 12.00

12.00

11.20

F2RP/F2FP/F3FP042

5,8,10,15 21

-

1200 36.0

27.2 12.00

12.00

11.30

YMA04211

F2FP048

5,8,10,15,20,25 24

-

1400

41.5

31.8

12.00 12.00 10.55

F2FP/F3FP060

8,10,15,20,25 24

-

1600

45.5

34.2

-

11.50

10.00

YMA04811

F2FP045

5,8,10,15 24

-

1600 45.5

34.5

-

12.00

10.20

YMA06011

F2FP060 8,10,15,20,25

24 -

1800

53.0

40.4

11.25

-

10.25

F2FV060 8,10,15,20,25

24 -

1780

54.0

40.8

12.00

-

10.75

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1

G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2

Single phase units require single phase 2HK heaters.

3

To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

4

FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.

Advertising