COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

UNIT MODEL

FURNACE**

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED CFM

TOTAL

CAPACITY

SENSIBLE
CAPACITY

SEER W/O TXV

+ TDR

1,2

SEER W/TXV

+ TDR

EER

YMA02411

600

1000

14

G1FA036S14

800

24.2

19.1

12.00

12.00

11.00

17,21

G1FA036S17,21

800

24.0

18.8

12.00

12.00

10.90

17

G2FD030(S,H)17(T)

800

24.0

18.8

12.00

12.00

10.90

14

G2FD035(S,H)14(T)

800

24.0

18.8

12.00

12.00

10.90

17

G1NA036S17J

800

24.2

18.8

12.00

12.00

11.00

21

G1NA036S21C

800

24.2

18.8

12.00

12.00

11.00

-

G1HD036

800

24.4

19.3

12.00

12.00

11.10

14

G1HA036H14

760

24.6

18.8

12.00

12.00

11.20

17

G1HA036H17

760

24.6

18.9

12.00

12.00

11.25

YMA03011

800

1200

17,21

G1FA036S14

1000

30.2

23.1

12.00

12.00

11.20

17,21

G1FA036S17,21

1000

30.0

23.0

12.00

12.00

11.10

17

G2FD030(S,H)17(T)

1000

30.0

23.0

12.00

12.00

11.10

14

G2FD035(S,H)14(T)

1000

30.0

23.0

12.00

12.00

11.10

17

G1NA036S17J

1000

30.4

23.0

12.00

12.00

11.25

21

G1NA036S21C

1000

30.4

23.0

12.00

12.00

11.25

-

G1HD036

1000

30.6

23.4

12.00

12.00

11.30

14

G1HA036H14

950

30.8

23.0

12.00

12.00

11.45

17

G1HA036H17

950

31.0

23.2

12.00

12.00

11.45

YMA03611

1000
1400

14

G1FA036S14(T)

1200

34.8

27.0

12.00

12.00

10.95

17,21

G1FA036S17,21(T)

1200

34.6

27.0

12.00

12.00

10.95

17

G2FD036(S,H)17(T)

1200

35.2

27.2

12.00

12.00

11.05

21

G2FD036(S,H)21(T)

1200

35.6

28.0

12.00

12.00

11.30

17

G1NA036S17J

1200

35.2

26.6

12.00

12.00

11.05

21

G1NA036S21C

1200

35.2

26.6

12.00

12.00

11.05

-

G1HD036

1200

35.4

27.4

12.00

12.00

11.10

14

G1HA036H14(T)

1140

35.6

27.2

12.00

12.00

11.30

17

G1HA036H17(T)

1140

35.8

27.4

12.00

12.00

11.40

YMA04211

1200
1600

21

G1FA048S21

1400

42.0

32.6

12.00

12.00

10.65

21,24

G2FD048(S,H)21,24

1400

42.0

32.8

12.00

12.00

10.70

24

G1NA060S24T

1400

42.5

33.0

12.00

12.00

10.90

-

G1HD048

1400

41.5

32.4

12.00

12.00

10.60

21

G1HA048H21

1330

41.5

31.6

12.00

12.00

10.60

YMA04811

1400
1800

21,24

G1FA060S21,24(T)

1600

46.0

35.6

-

12.00

10.20

24

G2FD060(S,H)24(T)

1600

46.0

35.6

-

12.00

10.20

24

G2FD061H24

1600

46.0

36.0

-

12.00

10.25

24

G1NA060S24T

1600

45.5

34.8

-

11.75

10.10

-

G1HD060

1600

45.0

35.0

-

11.75

10.10

24

G1HA60H24(T)

1520

45.5

34.8

-

12.00

10.20

YMA06011

1600
2000

21,24 G1FA060S21,24

1800

54.0

42.2

11.70

-

10.50

24 G2FD060(S,H)24

1800

54.0

42.2

11.70

-

10.50

24 G2FD061H24

1800 54.5 42.4

12.00

-

10.55

24 G1NA060S24T

1800

53.0

40.6

11.50

-

10.40

-

G1HD060 1800

53.0

41.1 11.50

-

10.35

24 G1HA60S24

1710 53.5 40.9

11.70

-

10.50

1

Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.

2

TXV = Use 1TV0700 series kit.

**

Refer to Quick Selection Chart for specific furnace match-up.