COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric

power input during the same period.

— = Not Applicable.

HEATING PERFORMANCE - With Air Handler

UNIT

MODEL*

AIR

HANDLER

COIL

1

MODEL

ARI HEATING

2

OUTDOOR TEMP

3

47

17.00

HSPF

-3 7 27 37 57

MBH COP KW MBH COP KW STD MBH KW MBH KW MBH KW MBH KW MBH KW

1 PH 12 SEER HP WITH N1AH/G2FD

YMA02411

N1AHB08 G2FD030(S,H)17(T) 24.0

3.46 2.03 13.8 2.44 1.66

8.00

7.0

1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16

N1AHB12 G2FD030(S,H)17(T) 24.0

3.46 2.03 13.8 2.44 1.66

8.00

7.0

1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16

YMA03011

N1AHB08 G2FD030(S,H)17(T) 30.0

3.28 2.68 17.8 2.44 2.14

8.00

9.8

1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86

N1AHB12 G2FD030(S,H)17(T) 30.0

3.28 2.68 17.8 2.44 2.14

8.00

9.8

1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86

N1AHB08 G2FD036(S,H)17(T) 35.2

3.54 2.91 21.0 2.54 2.42

8.00

11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08

YMA03611

N1AHB12 G2FD036(S,H)17(T) 35.2

3.54 2.91 21.0 2.54 2.42

8.00

11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08

N1AHC16 G2FD036(S,H)21(T) 35.2

3.54 2.91 21.0 2.54 2.42

8.00

11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08

YMA04211

N1AHC16 G2FD048(S,H)21(T) 42.0

3.50 3.52 28.2 2.50 3.31

8.00

18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63

N1AHD20 G2FD048(S,H)24(T) 42.0

3.50 3.52 28.2 2.50 3.31

8.00

18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63

YMA04811

N1AHD20 G2FD060(S,H)24(T) 48.0

3.66 3.84 31.0 2.52 3.60

8.00

19.7 3.44 25.3 3.52 33.6 3.59 36.1 3.57 53.7 3.94

N1AHD20 G2FD061H24

48.0

3.66 3.84 31.0 2.52 3.60

8.00

19.7 3.45 25.4 3.53 33.7 3.60 36.3 3.58 53.9 3.95

YMA06011

N1AHD20

G2FD060(S,H)24(T) 59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83

N1AHD20

G2FD061H24

59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83

1 PH 12 SEER WITH N1VS - VARIABLE SPEED

YMA02411

N1VSB12 G2FD030(S,H)17(T) 23.4

3.70 1.85 13.3 2.64

1.48

8.50

6.5

1.23

9.9

1.36 15.4 1.55 17.4 1.62 26.9 1.98

YMA03011

N1VSB12 G2FD030(S,H)17(T) 29.4

3.46 2.49 17.5 2.60

1.97

8.50

9.6

1.63 13.6 1.81 20.1 2.10 22.6 2.22 33.5 2.67

YMA03611

N1VSB12 G2FD036(S,H)17(T) 34.8

3.70 2.76 20.6 2.68

2.25

8.50

11.3 1.95 16.1 2.12 23.0 2.38 25.2 2.48 39.7 2.94

N1VSC16 G2FD036(S,H)21(T) 34.8

3.76 2.71 20.6 2.72

2.22

8.50

11.2 1.90 15.9 2.06 22.9 2.32 25.1 2.42 39.6 2.88

YMA04211

N1VSC16 G2FD048(S,H)21(T) 41.0

3.64 3.30 27.2 2.60

3.07

8.50

17.9 2.92 22.6 3.00 28.4 3.04 29.5 3.00 45.9 3.39

N1VSD20 G2FD048(S,H)24(T) 41.0

3.68 3.26 27.4 2.62

3.06

8.50

18.1 2.91 22.8 2.99 28.5 3.03 29.7 2.99 46.1 3.38

YMA04811

N1VSD20 G2FD060(S,H)24(T) 47.0

3.82 3.60 30.2 2.60

3.40

8.50

19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67

N1VSD20 G2FD061H24

47.5

3.80 3.70 30.8 2.64

3.42

8.50

19.5 3.27 25.2 3.36 33.5 3.42 36.0 3.41 53.7 3.78

YMA06011

N1VSD20

G2FD060(S,H)24 58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77

N1VSD20

G2FD061H24

58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77

1 PH 12 SEER HP / F2RP / RC / FP / FC /FV

YMA02411

F2RC/F2FC036 -

24.0

3.46 2.03 13.8 2.44 1.66

8.00

7.0

1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16

F2RP/F2FP/F3FP024

-

23.6

3.46 2.00 13.4 2.44 1.61

8.00

7.0

1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16

F2RP/F2FP/F3FP030

-

24.0

3.46 2.03 13.8 2.44 1.66

8.00

7.0

1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16

YMA03011

F2RC/F2FC036

-

30.0

3.30 2.66 17.6 2.42 2.13

8.00

9.4

1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.84

F2RP/F2FP/F3FP030

-

30.0

3.32 2.65 17.6 2.42 2.13

8.00

9.4

1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.83

YMA03611

F2FP/F3FP040

-

35.0

3.54 2.90 20.8 2.54 2.40

8.00

11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07

F2RP/F2FP/F3FP036

-

34.8

3.52 2.90 20.6 2.50 2.41

8.00

11.2 2.09 15.9 2.26 22.9 2.52 25.1 2.61 39.6 3.07

F2RP/F2FP/F3FP042

-

35.0

3.54 2.90 20.8 2.54 2.40

8.00

11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07

YMA04211

F2FP048

-

41.5

3.46 3.51 27.8 2.48 3.28

8.00

18.7 3.14 23.3 3.22 29.1 3.26 30.2 3.22 46.6 3.63

F2FP/F3FP060

-

47.5

3.58 3.89 30.8 2.48 3.64

8.00

19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99

YMA04811

F2FP045

-

47.5

3.68 3.78 30.8 2.54 3.55

8.00

19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99

F2FV060

-

47.0

3.82 3.60 30.2 2.60 3.40

8.50

19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67

YMA06011

F2FP060

-

59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83

F2FV060

-

58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77

1

Rated CFM same as for cooling.

2

Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental
electric heat operation.

3

Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.