Zanussi ZHC 916X User Manual

Page 16

Advertising
background image

16

Air outlet directed upwards (Fig. 2a-b):

-

Remove the plastic plug from the upper part of
the venting grill and replace it on the rear part (Fig.
16
).

Air outlet directed towards the wall (Fig. 3):

-

Remove the plastic frame from the air outlet (Fig.
17
).

-

Remove the plug from the upper part of the ducting
fan unit (Fig. 18), as it is not possible to insert the
flange F with the plug in place.

-

Fit the flange F Ø 120 or 150 mm (Fig. 19), replace
the plug.

Air outlet directed to the left or right hand side (Fig. 4a-
b
):

-

Remove the four screws fastening the plastic fra-
me, as shown in Fig. 17.

-

Fit the ducting spigot R (Fig. 20) and replace the
four screws removed as above.

INSTALLATION INSTRUCTIONS

16

17

18

19

20