DUCT CONNECTORS

INSTALLATION OF SCREW ATTACHMENT DUCT

CONNECTOR

1.

Make floor cut out as shown in Figure 8.

2.

Determine the depth of the floor cavity from the surface of the floor
to the top of the supply air duct and select the appropriate duct
connector from the chart.

3.

Place locating bracket (supplied with the duct connector) to the
back edge of the floor opening. See Figure 10.

4.

Apply a water based duct sealant to the 1/2 in (1.3 cm) supply duct
attachment flange of the duct connector.

5.

Determine which of the four positions the duct connector best cen-
ters over the supply duct and insert it through the floor cut-out.

6.

When properly aligned with the supply duct, secure the duct con-
nector to the floor with nails, flat head screws or staples.

7.

Use screws as required to secure the duct connector to the supply
duct.

8.

Cut out the opening to the supply duct. If sealant was not used, the
installer should tape the mating flanges to provide a good air seal.

NOTE: Duct sealant and tape must be classified as meeting HUD Stan-
dard 3280.715, U.L. Standard 181A.

If tape is used to provide a better air seal, it should be a type approved
by the applicable national or local codes.

FIGURE 7: Duct Connector Dimensions

2-3/8
(6.0 cm)

12

(30.5 cm)

13

(33.0 cm)

11

(27.9 cm

18-3/4 (47.6 cm)

14 (35.6 cm)

SEE
CHART

DUCT CONNECTOR

PART NUMBER

DUCT CONNECTOR

DEPTH

7990-6011
7990-6021
7990-6041
7990-6061
7990-6071
7990-6081
7990-6101
7990-6121

1” (2.5 cm)
2” (5.7 cm)

4-1/2” (11.4 cm

6-1-2” (16.5 cm)
7-1/2” (19.0 cm)
8-1/2” (21.6 cm)

10-1/4” (26.0 cm)
12-1/4” (21.1 cm)

DUCT CONNECTOR DIMENSIONS

2-3/8

(6.0 cm)

18-3/4

(47.6 cm)

4-3/8
(11.1 cm)

2-3/8
(6.0 cm)

12

(30.5 cm)

13

(33.0 cm)

11

(27.9 cm

18-3/4 (47.6 cm)

14 (35.6 cm)

SEE
CHART

DUCT CONNECTOR

PART NUMBER

DUCT CONNECTOR

DEPTH

1” (2.5 cm)
2” (5.7 cm)

4-1/2” (11.4 cm

6-1-2” (16.5 cm)
7-1/2” (19.0 cm)
8-1/2” (21.6 cm)

10-1/4” (26.0 cm)
12-1/4” (21.1 cm)

DUCT CONNECTOR DIMENSIONS

2-3/8

(6.0 cm)

18-3/4

(47.6 cm)

4-3/8
(11.1 cm)

7990-6211
7990-6221
7990-6241
7990-6261
7990-6271
7990-6281
7990-6301
7990-6321

FIGURE 8: Recommended Floor Cut-out

FIGURE 9: Duct Connector Depth

2-3/4 (7.0 cm)

Min.

23-1/4

(59.1

cm)

20-1/2

(52.1

cm)

9-7/8

(25.1

cm

1-3/8

(3.5 cm)

6-3/8

(16.2 cm)

9-3/4

24.8 cm)

20

(50.8 cm)

1-1/8
(2.9 cm)

15

(38.1 cm)

15

(38.1

cm)

1

Rear Wall
of Enclosure

Ceiling Cut-Out
For Roof Jack

Floor Cut-Out
For Duct
Connector

Floor

Future
Refrigerant
Line Entrance

Front Panel
of Furnace

3-1/4

(8.3 cm)

Furnace
Outline

Optional Gas
or Electric
Entrance

2-1/8 (5.4 cm)

Duct Connector

Depth

Floor

Floor
Joist

Supply Duct

FIGURE 10: Duct Connector Screw Attachment

Locator Bracket

Nails, Flat Head Screws
or Staples

Screws

Floor

Supply Duct