Zebra Technologies R110Xi User Manual

Page 70

Advertising
background image

58

R110Xi/R170Xi User Guide

23063L-003 Rev. 1 12/6/04

Front Panel Controls

Front Panel LCD

RESYNCH MODE

Resynch Mode
This parameter determines how the printer reacts if the label synchronization is lost
and the label top is not where expected.

Feed Mode—If the label top is not where expected, the printer feeds a blank

label to find the label top position.

Error Mode—If the label top is not where expected, the printer stops, enters

Pause Mode, displays the message

Error Condition Feed Label

,

flashes the

ERROR

light, and asserts the Service Required signal (pin 10 on

the Applicator Interface Connector).

To resynch the media to the top of the label in Error Mode, press PAUSE to exit
Pause Mode. The

ERROR

light stops flashing, and the Service Required signal

is deactivated. The action of the printer is determined by the

Head Close

configuration selection (see

Head Close on page 54

).

• Press the right or left oval to toggle between choices.
Default: FEED MODE
Selections: FEED MODE, ERROR MODE

WEB S.

These parameters are automatically set during the calibration procedure. They
should be changed only by a qualified service technician. See the Maintenance
Manual
for more information on these parameters.
• Press NEXT/SAVE to scroll through these parameters.

MEDIA S.

RIBBON S.

TAKE LABEL

MARK S.

MARK MED S.

MEDIA LED

RIBBON LED

MARK LED

LCD ADJUST

Adjust LCD Contrast
This parameter allows you to adjust the contrast of your LCD if it is difficult to
read.

1.

Press the left oval to move the cursor.

2.

Press the right oval to toggle +/- or to increase the value of the digit.

Range: 00 to 19

FORMAT CONVERT

Select Format Conversion Factor
Selects the bitmap scaling factor. The first number is the original dots per inch (dpi)
value; the second, the dpi to which you would like to scale.

Note •

Not applicable on all printers.

• Press the right or left oval to display other choices.
Default: None
Selections:

None, 150

→ 300, 150 → 600, 200 → 600, 300 → 600

Table 7 • Standard LCD Displays (Page 15 of 16)

Parameter

Action/Explanation