York YHJD18 User Manual

Page 17

Advertising
background image

Johnson Controls Unitary Products

17

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.

YHJD

48S41S1

T*(8,L)X*C16

FC/PC60C

47.0

3.46

3.98

32.8

2.28

4.22

8.00

T*9X*C16

FC/PC60C

47.0

3.46

3.98

32.8

2.28

4.22

8.00

T*(8,L)X*C20

FC/MC/PC60D

47.0

3.48

3.96

32.8

2.28

4.22

8.00

T*9X*C20

FC/PC60C

47.0

3.48

3.96

32.6

2.30

4.15

8.00

T*9X*D20

FC/MC/PC60D

46.5

3.50

3.89

32.2

2.32

4.07

8.10

T*9X*D20

FC/MC62D

47.5

3.54

3.93

32.6

2.30

4.15

8.00

T*(8,L)X*C16

UC60C

47.5

3.58

3.89

32.6

2.34

4.08

8.10

T*(8,L)X*C20

UC60D

47.0

3.64

3.78

32.0

2.40

3.91

8.10

T*9X*C16

UC60C

47.5

3.58

3.89

32.6

2.34

4.08

8.00

T*9X*C20

UC60C

47.5

3.60

3.87

32.6

2.34

4.08

8.10

T*9X*D20

UC60D

46.5

3.60

3.79

32.0

2.38

3.94

8.10

(

Y

*9C/T*9V)*D20

FC/MC/PC60D

47.5 3.38 4.12 30.4 2.38 3.74 8.50

(

Y

*9C/T*9V)*D20

FC/MC62D 48.0 3.44 4.09 30.2 2.40 3.69 8.50

Y

*(8,L)C*C16 FC/PC60C 47.5 3.40 4.09 30.4 2.40 3.71 8.50

Y

*(8,L)C*C20 FC/PC60C 47.5 3.46 4.02 30.2 2.42 3.66 8.60

(

Y

*9C/T*9V)*C16

FC/PC60C 48.0 3.38 4.16 30.6 2.38 3.77 8.50

(

Y

*9C/T*9V)*C20

FC/PC60C 48.0 3.38 4.16 30.6 2.38 3.77 8.50

(

Y

*9C/T*9V)*D20 HC60

48.0 3.48 4.04 30.4 2.44 3.65 8.50

Y

*(8,L)C*C16

HD60

47.0 3.22 4.28 30.2 2.24 3.95 8.40

Y

*(8,L)C*C20

HD60

47.0 3.24 4.25 30.0 2.28 3.86 8.40

(

Y

*9C/T*9V)*C16 HD60

47.5 3.18 4.38 30.2 2.24 3.95 8.40

(

Y

*9C/T*9V)*C20 HD60

47.5 3.18 4.38 30.2 2.24 3.95 8.40

(

Y

*9C/T*9V)*D20 HD60

47.5 3.20 4.35 30.2 2.24 3.95 8.40

Y

*(8,L)C*C16 UC60C

47.5 3.46 4.02 30.2 2.42 3.66 8.50

Y

*(8,L)C*C20 UC60C

47.5 3.52 3.95 30.0 2.46 3.57 8.60

(

Y

*9C/T*9V)*C16 UC60C

48.0 3.44 4.09 30.4 2.42 3.68 8.50

(

Y

*9C/T*9V)*C20 UC60C

48.0 3.44 4.09 30.4 2.42 3.68 8.50

(

Y

*9C/T*9V)*D20 UC60D

48.0 3.44 4.09 30.2 2.42 3.66 8.50

YHJD

60S41S1

T*(8,L)X*C20

FC/MC62D

56.5

3.60

4.60

32.6

2.46

3.88

8.10

T*9X*D20

FC/MC62D

56.5

3.44

4.81

34.0

2.34

4.26

8.00

(

Y

*9C/T*9V)*D20

FC/MC/PC60D

55.5 3.30 4.93 35.0 2.40 4.27 8.50

Y

*(8,L)C*C20 FC/MC62D 55.5 3.42 4.76 34.6 2.44 4.16 8.60

(

Y

*9C/T*9V)*C20

FC/MC62D 56.0 3.36 4.88 35.0 2.40 4.27 8.60

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.

HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)

MODEL

FURNACE

MODEL

COIL

1

MODEL

ARI HEATING

2

47

F

17

F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

Advertising