Lt2002 clone programmer, Clone programmer/cloning procedure troubleshooting – Zenith HEALTHVIEW H20J55DT User Manual

Page 55

Advertising
background image

Page 55

206-4065

When cloning operations are complete, just unplug the LT2000 from the TV.

If the TV does not display a picture (blank screen) after a few seconds, just change channels.

LT2002 Clone Programmer

Clone Operation Notes

Disconnect the Clone from the TV when you are

finished; automatically switching it off. The real-

time clock continues to run after the main circuits

are switched off.

Reset Clone After Static Shock

After replacing exhausted batteries, or if the pro-

grammer behaves strangely after a static shock,

use a paper clip or similar instrument inserted

through the small hole marked ”RESET” to activate

the internal reset switch and restore normal opera-

tion.

After a reset, check the real-time clock setting. It

may be necessary to reset the Clone Programmer

clock from a TV containing the correct time.

The LT2002 programmer is designed to be used

with TV's containing the 221-01006 and later

processors. Use with earlier TV sets may give

unpredictable results. The specific microprocessor

used in any TV set may be determined by activat-

ing the Installer Menu. The microprocessor part

number appears on the screen when the Installer

Menu is activated. Processors before the 221-

01006-04 have a limited screen display capability.

They can not display entire screens as shown in

the quick setup instructions accompanying the

LT2002 clone programmer. Use the printed menu

illustrations on the quick setup sheet supplied with

the Clone as an aid to making your programming

choices. ( Although the menus are not all dis-

played, the clone functions all operate normally).

Clone Programmer/Cloning Procedure Troubleshooting

Problem

Possible Cause(s)

Possible Solution(s)

Clone Programmer

LED does not blink.

• M.P.I. cord not connected.

- Connect M.P.I. cord.

• TV not turned On.

- TV must be On for clone to work.

• Weak batteries.

- Install 4 fresh AA high-quality alkaline

batteries.

Clone menu hard

• Weak signal.

- Connect TV to a reliable signal Source.

to read.

No time set.

• No time on Master TV.

- Set time on master TV, copy time to Clone

Programmer.

Menu items 7-8 not

• Not necessary.

- Channel Labels already cloned; if they were

on clone selection menu.

on Master TV.

Master and Other TV's

Cloning did not work.

• Procedure interrupted.

- Wait until procedure complete message is

displayed.

• Different TV models.

- Cloning is only possible with identical model

Zenith TV's.

Clone time disappeared.

• Batteries were removed.

- Batteries must remain installed to retain time

settings.

New Setup not present.

• TV not reset.

- Disconnect newly-cloned TV from power for

15 seconds.

Digital information not

• 2-5-5 + Menu not done.

- Redo setup and 2-5-5 + Menu as required.

present.