User instructions, Cleaning glass, Chimney sweeping – Yeoman YM-CL8HB User Manual

Page 12: Chimney fire, General cleaning

Advertising
background image

12

Check that the door shuts properly and creates an effective

seal. Leaking door seals prevent the appliance working

properly.

Do not use aerosol sprays near an operating appliance.

13. CLEANING GLASS

Keep the glass clean with correct use of the Airwash system

and good quality fuel.

13.1 Sometimes additional cleaning may be required.

This can be done as follows:

Allow appliance to cool fully. Do not clean hot glass.

Use a soft cloth and Stovax Glass Cleaner.

13.2 Before re-lighting the appliance dry the glass fully.

13.3 Do not use abrasive cleaner or cleaning pads.

14. CHIMNEY SWEEPING

14.1 To maintain safe and efficient use of the appliance, the

chimney/flue must be inspected and swept at least once a

year by a qualified chimney sweep**.

If the appliance is used continuously throughout the year,

or it is used to burn wood or smokeless fuel, more frequent

sweeping is recommended.

The best time to have the chimney swept is at the start of

the heating season.

The above applies even if burning smokeless fuels.

14.2 The chimney, any connecting flue pipe and the appliance

flue ways, if incorporated, must be regularly cleaned.

14.3 Ensure adequate access for cleaning where it is not possible

to sweep through the chimney.

14.4 If the chimney is believed to have previously served an

open fire it must be swept a second time within a month of

regular use after installation.

11. CHIMNEY FIRE

11.1 If a chimney fire occurs:

Shut all air controls immediately.

Evacuate the building.

Call the fire brigade.

Do not re-enter the building until it is confirmed safe.

11.2 Do not use the appliance after a chimney fire until:

a) It has been inspected by a registered installer*,

confirming the appliance is safe to use.

b) The chimney system has been inspected and swept by a

chimney sweep, confirming the system is structurally sound

and free from obstruction**.

c) It is repaired as required before re-use. Use only

genuine Yeoman replacement parts to keep your appliance

in safe, efficient working order.

12. GENERAL CLEANING

12.1 Clean and inspect the appliance regularly, especially in

periods of heavy use. Regular cleaning and maintenance

will help give many years of safe use.

Allow appliance to cool thoroughly to avoid risk of burns.

Clean regularly, according to level of use.

Remove the ash completely (see User Instructions,

Section 7).

Check the internal components for damage. Do not use

the appliance if any parts are broken or damaged. Replace

damaged parts with genuine Yeoman replacement parts to

keep the appliance in safe, efficient working order.

Check for obvious build up of soot, ash or debris above the

flue baffle(s) (these can be found in the upper part of the

firebox). Use a torch if necessary.

If there are any signs of a build up of debris above the flue

baffle(s) either:

Arrange for the chimney to be swept (see User

Instructions, Section 14).

Remove the baffle and clear the debris (see Installation

Instructions, Section 3).

To refresh painted finishes use Stovax Riva Midnight black

metallic paint.

Wipe dry with a soft clean cloth be fore relighting. Always

dry appliance to avoid rust.

Do not use abrasive cleaner or cleaning pads.

USER INSTRUCTIONS

In the U.K.

* Registered on the Competent Persons Scheme (GB only)

see page 35 / INFO (Republic of Ireland).

** This should be done by a HETAS registered chimney

sweep, see page 35, who will issue you with a certificate.

Advertising