2. REMOVAL OF THE LOG GUARD

2.1 To remove the Log guard:

Lift Log Guard clear of the supporting brackets.

Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

3. FITTING AND REMOVAL OF BAFFLE

4.1 See Installation Instructions, Section 3.

4.2 It is important to remove and clean the Baffle system to

ensure the flue ways are clear of soot and debris and to

ensure the safe and efficient operation of the stove. The

frequency of cleaning depends on the stove operating

conditions.

4.3 The baffle system is designed to give safe and efficient

operation of the stove. Replace any damaged baffle

immediately.

4.4 Do not modify the baffle system.

5. FITTING A NEW DOOR GLASS

5.1 To maintain safe use of the appliance damaged door glass

must be replaced immediately. To do this:

Open door and lift free of hinge blocks.

Lay door face down on a soft flat surface to protect the

paintwork and glass.

Remove the glass clamp and screws x 8. The old

glass can then be lifted clear of the door. Note how the

sealing rope is placed around the glass.

Dispose of the old glass safely.

MAINTENANCE and SERVICING

Fixing Screws x 8

Door

PR8738

Glass rope

seal

B

Seal

Length (mm)

Glass rope seal A

1220

Glass rope seal B

460

PR8739

Glass rope

seal

B

Black face

PR8757

Glass rope seal

A

Glass rope

seal

A