Site requirements, Walls next to a hearth – Yeoman YM-CL8HB User Manual

Page 19

Advertising
background image

19

SITE REQUIREMENTS

WALLS NExT TO A HEARTH

Position of Appliance & Hearth in relation to walls

Requirement for the walls

Distance of hearth from wall

'C'

Distance of Appliance to wall

Min thickness of Wall

'W'

Min height of wall

'H'

0mm

0mm - 50mm

200mm

Height of appliance + 300mm

Or

1200mm from the hearth (take largest

dimension)

0mm

51mm - 300mm

75mm

0 - 150mm

150mm +

75mm

1200mm

150mm +

300mm +

No Minimum Requirement

Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance.

Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.

Solid, non-combustible

material e.g. masonry or

concrete

Thickness W

C

150mm

minimum

150mm

minimum

C

H

PR8731

PR8589

80mm

Note:

When installing a Multi-fuel appliance a

minimum gap of 80mm must be left on the

Right Hand Side so that the riddling tool

can be comfortably engaged in the socket.