Zephyr Layers Wall ALA - M90ABX User Manual

Page 19

Advertising
background image

6. Insert the 6 pin female molex connector into the

junction box. See Fig. 6A. Secure remote blower
junction box to top of blower housing using (2)
screws. See Fig. 6B

7. Feed remote blower wire harness through remote

blower junction box cover and Connect the wires
with those inside the junction box. See Fig. 7

Note: Carry out the power supplly con-

nection in accordance with the natio-
nal electric code, ANSI/NFPA 70-1999.

8.Secure cover to junction box using (2)

screws.

Note1: A cable lock (not included) may

be required by local codes. Please
review local codes for more informa-
tion.

9. Attach 6 pin male molex connectors to 6 pin fe-

male molex connectors inside blower housing.
See Fig. 8

Note2: Check local codes to determine minimum
wire gauge.

See manual included with external and in-line
blower for instructions on installing the
blower.

Installa

tion - Ex

ternal & In-Line Blo

w

er P

repar

a

tion

- 19 -

Advertising
This manual is related to the following products: