GENERAL

• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations.

POWER SUPPLY CONNECTION

For connection to the power supply refer to
the following:

1. Lift the bottom part of the duct cover and

secure it carefully using adhesive tape.

2. Remove the power supply cover by un-

doing the (2) screws Fig. 11.

3. Break through the hole on the box co-

ver.

4. Secure the power supply conduit to the

cover.

5. Connect the wires of the hood to those of

the power supply as described. Fig.11:

BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground

- A double-pole switch properly rated must

be installed to provide the range hood
power supply disconnection.

- Connect the electrical conduit to the Field

Wiring Compartment using listed onduit
fi ttings.

- Carry out the power supplly connection in

accordance with the national electric code,
ANSI/NFPA 70-1999.

6. Insert the wires into the box, then close the box cover, securing it using the

screws that were previously removed.

7. Remove the adhesive tape from the chimney and place the lower part of the

chimney on the hood.