Manual calibration is recommended whenever you are using pre-printed
media or if the printer will not correctly auto calibrate.

1. Make sure media is loaded.

2. Turn on the printer power.

3. Press and hold the feed button until the green status LED flashes once,

then twice. Release the feed button.

4. The printer will set the media sensor for the label backing being used.

After it is done making this adjustment, the roll will automatically feed
until a label is positioned at the print head.

5. A profile of the media sensor settings (similar to the example below)

will print. Upon completion, the printer will save the new settings in
memory and the printer is ready for normal operation.

6. Press the feed button. One entire blank label will feed. If this does not

happen, try defaulting (refer to the four-flash sequence in “Feed Button
Modes” on page 43) and recalibrating the printer.

NOTE: Performing a manual calibration disables the auto calibration

function. To return to auto calibration, default the printer (see the
four-flash sequence in “Feed Button Modes” on page 43).