4 .system with cross-connect option, 1 circuit diagnostics, System with cross-connect option -4 – Zhone Technologies IMACS-200 User Manual

Page 248: Circuit diagnostics -4, System with cross-connect option

Advertising
background image

14-4

Diagnostics

Model No.

Running Head

.System with Cross-Connect Option

System Testing and Diagnostics

14.4

.

System with Cross-Connect Option

14.4.1 Circuit Diagnostics

In systems equipped with Cross-Connect CPUs, the cross-connect element adds another level
of testing within the node and enhances the system’s diagnostic capabilities. The operator may
also monitor and set the state of the Transmit and Receive ABCD signaling bits of a digitized
voice circuit that is cross-connected between WANs. The table below shows detailed
information on the diagnostic capabilities of the circuits.

Voice

without

Signaling

Voice with

Signaling

Single Data

DS0

(64 Kbps)

Super-rate

Data

(N x 64 Kbps)

Loopbacks

Local loopbacks

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

Bit Error Rate Tester (BERT)

Patterns Supported

All 1s

Yes

Yes

Yes

Yes

All 0s

Yes

Yes

Yes

Yes

1:1

Yes

Yes

Yes

Yes

1:7

Yes

Yes

Yes

Yes

M_OOS

Yes

Yes

Yes

Yes

BERT Direction

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

Tones Supported

300 Hz

Yes

Yes

Yes

Yes

1 kHz

Yes

Yes

Yes

Yes

3 kHz

Yes

Yes

Yes

Yes

Tone Direction

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

Advertising