CFBLOCK = ?
CFBLOCK : CALL FORWARD BLOCKING
CHARACTERISTIC : OPTIONAL
POSSIBLE VALUES : ENABLED CALL FORWARD BLOCKING ENABLED
DISABLED CALL FORWARD BLOCKING DISABLED
CFBLOCK = DISABLED

ADD-TGACC:100,NONE,C-HAWK,23,BOTH,TERR,,,0,ROUND,;
H500: AMO TGACC STARTED
H1: TRUNK GROUP 100 HAS BEEN CREATED
AMO-TGACC-111 TRUNK GROUP ACCESS CODE
ADD COMPLETED;

Display Trunk Group Access Codes:

<dis-tgacc

TGRP =100;
DIS-TGACC:100;
H500: AMO TGACC STARTED
+-------------------------------------------------------------------------+
| TGRP NUMBER : 100 TGRP NAME : CHAWK /N MAXIMUM NO: 23 |
| SUBGROUP NUMBER: 3 DEVICE TYPE: PRI B DIR TYPE : BOTH |
| ACD THRESHOLD : * TRACENO : 0 USAGE TYPE: TERR |
| ALLOCATED TO AT LEAST ONE ROUTE GDTR RULE : 0 |
| SELECTION : ROUND CFBLOCK : DISABLED
|
| THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED:
|
+-------------------------------------------------------------------------+
|1-1-73-1 | 1-1-73-2 | 1-1-73-3 | 1-1-73-4 | 1-1-73-5 | 1-1-73-6 |
+-------------------------------------------------------------------------+
|1-1-73-7 | 1-1-73-8 | 1-1-73-9 | 1-1-73-10| 1-1-73-11| 1-1-73-12|
+-------------------------------------------------------------------------+
|1-1-73-13| 1-1-73-14| 1-1-73-15| 1-1-73-16| 1-1-73-17| 1-1-73-18|
+-------------------------------------------------------------------------+
|1-1-73-19| 1-1-73-20| 1-1-73-21| 1-1-73-22| 1-1-73-23|
+-------------------------------------------------------------------------+
AMO-TGACC-111 TRUNK GROUP ACCESS CODE
DISPLAY COMPLETED;

Add COP (Class of Parameters):

<add-cop

COPNO = 100
PAR = ;
ADD-COP:100,;
H500: AMO COP STARTED
H1: COP 100 IS NOW SET UP
AMO-COP -111 CLASS OF PARAMETER
ADD COMPLETED;