P-5 installing the extension module, Installation of the extension module, Mounting the sdi box on the monitor – MITSUBISHI ELECTRIC LDT462V User Manual

Page 26: Connection with sdi

Advertising
background image

English-22

Extension module

Option slot

Option slot

SDI BOX

P-5

Installing the extension module

Carry out as necessary

SDI for long-distance connection

or multiple-monitor connection

1. Mounting the SDI BOX on the monitor

1. Turn off the main power switch of the monitor and

disconnect the power cord.

CAUTION:

Be sure to disconnect the power cord to prevent breakdown

and electric shock.

2. Use a Phillips screwdriver to unscrew and remove the

option slot cover.

Retain the screw for later use in step 4.

3. Mount a SDI BOX (option) in the option slot of the monitor.

CAUTION:

To prevent damage, please ensure proper orientation and

position of the SDI BOX before inserting it fully into the slot.

4. Reuse the two screws removed from step 2 and properly

secure the SDI BOX.

2. Connection with SDI

There are two cases of connection.

1) Connection to one monitor

1. Connect the video device and the SDI BOX (option) using

an SDI cable (BNC) (commercially available).

NOTE:

A high-spec BNC cable capable of carrying SDI signal is called

SDI cable and distinguished from other BNC cables.

2) Connection to multiple monitors

1. After the connection made in 2-1) above, connect the

SDI OUT connector on the fi rst SDI BOX and the SDI IN

connector on the second SDI BOX using a commercially

available SDI cable (BNC).

NOTE:

The usable cable length (when SDI BOX (DP-1SDI-3G) is

mounted) is as follows:

• When one SDI BOX is connected: 100 m (3G-SDI)*

* Based on the result of the actual measurement using

the recommended cable. (Recommended cable: 1694A

made by Belden)

NOTE:

For the connection method and specifi cations of the SDI BOX,

see the catalog or operation manual of the SDI BOX.

Removal of the SDI BOX

Hold the handle on the SDI BOX for removal.

CAUTION:

Use the handle to extract the SDI BOX only. Pulling on the SDI

cable (BNC) or by other means may cause damage.

Installation of the extension module

Install the extension module to the option slot of this monitor

following the precautions and procedures described in the

manual supplied with the module.

Examples of supported extension modules:

• SDI BOX (DP-1SDI-3G)

• OPS-compliant computer (commercially available)

Recommended computer (commercially available):

ARK-DS220F-MTSA1E of Advantech Co., Ltd.

NOTE:

• Please contact module manufacturer for any compatibility

issues.

[Description]

Intel

®

OPS (Open Pluggable Specifi cation) is a standard

suggested by Intel Corporation regarding the interface between

the pluggable module mounted on monitors designed for digital

signage applications and the monitors.

Supported OPS features:

• DVI-D

• Power control

• UART

NOTE:

When an OPS-compliant module is in the option slot, the

monitor doesn’t enter the sleep mode even when POWER SAVE

in the CONFIGURATION1 menu is set to ON. Even when other

video input is selected, the monitor doesn’t enter the sleep

mode. See pages 29 and 48.