Accusys ACS-7630 User Manual

Page 28

Advertising
background image

Accusys 7630

28

A

A

p

p

p

p

e

e

n

n

d

d

i

i

x

x

A

A

F

F

F

A

A

A

Q

Q

Q

If you encounter a problem while using the ACS-7630, check this section for help.

1. When I lock a drive carrier with a disk drive in place, the red disk activity indicator

turns on and an alarm beep sounds. Why?

(a) Make sure you firmly connect the IDE and Power connectors of the HDD to their

counterparts inside the drive carrier and try again. If this does not solve the situation,

go to (b).

(b) Change the disk drive with a new one and try again.

(c) Exchange the top and bottom drive carriers and try again to determine if the carrier

itself is faulty.

(d) If all of the above steps fail, contact your vendor.

2. How can I turn off the alarm beep sound when there is a hard disk failure?

Unlock the drive carrier of the failed disk. This will turn off the alarm beep sound.

3. I use a 60cm IDE cable to connect the ACS-7630, but the system shows some error

messages and the hard drive can’t be accessed normally. Why?

The specifications of ACS-7630 are based on ATAPI specifications. To ensure good IDE

signal quality, the length of your IDE cable cannot be longer than 46 cm (18 inch).

4. I have connected the RAID controller, but it does not appear in the motherboard

BIOS. Why?

Ensure that an array is initialized.

5. Why does ACS-7630 not recognize the HDDs?

There may be an HDD jumper-setting problem. Make sure all drive jumpers are set to

"master"

Advertising