Fault isolation, A. troubleshooting guidelines, Table 6. troubleshooting guide – ACR&Artex ELT to Nav Interface User Manual

Page 38

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC.

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

453-6500

25-69-10

Page 38 of 58

APR 30/12

TASK 25-69-10-810-801

6. Fault Isolation

SUBTASK 25-69-10-810-001

A. Troubleshooting Guidelines

(1)

Table 6 provides ELT troubleshooting guidelines for installation and operational issues.

Table 6. Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

POSSIBLE SOLUTION

ELT and remote switch LED

display 5-flash error

(No navigation data present)

Aircraft navigation system off

Turn on navigation system

No power to ELT/NAV Interface

Turn on power

Check breaker/fuse

Faulty interface wiring or

connections

Check for frayed insulation

causing short or ground

Verify integrity of all crimp and

solder connections

Check wiring continuity and

repair as necessary

ELT and remote switch LED flash

rapidly within two minutes after

ELT/NAV Interface power up

(24-bit address not accepted)

ELT not programmed for 24-bit

address location protocol

Program ELT with 24-bit address

location protocol

Faulty interface wiring or

connections

Check for frayed insulation

causing short or ground

Verify integrity of all crimp and

solder connections

Check wiring continuity and

repair as necessary

Advertising