Figure 8 performance testing equipment setup, H. 121.5 mhz frequency measurement – item 5a – ACR&Artex C406-2 HM User Manual

Page 41

Advertising
background image

25-62-11

Page 41 of 87

JUN 20/13

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-2 (453-5000), C406-2HM (453-5001)

By doing so, the three-minute warm-up requirement can be eliminated from a number of

tests and battery run time minimized to a large extent.

(1)

Place the ELT in a container or screen room capable of substantially attenuating RF signals, or

the transmitter power output shall be connected to a suitable dummy load to minimize

radiation.

(2)

Use the ELT’s own battery pack as the power source for these measurements. An alternate

power source can be used where lengthy servicing, other than the performance tests, is

anticipated.

(3)

Ensure that adequate attenuation rated for 406 MHz is installed between the ELT antenna

output and the measurement equipment to prevent damaging input circuitry, if required. At a

minimum, the attenuator should be rated at 30 dB, and 5 watts for a ½-second duration. As

shown in Figure 8.

Figure 8 Performance Testing Equipment Setup

SUBTASK 25-62-11-750-003

H. 121.5 MHz Frequency Measurement – Item 5a

(1)

Connect the measuring device, referring to SUBTASK 25-62-11-750-002 on page 40.

(2)

Activate the ELT by placing the control switch in the “ON” position.

(3)

Wait three minutes.

(4)

Perform SUBTASK 25-62-11-750-004 during the three-minute waiting period.

(5)

Measure the frequency after the three-minute waiting period. The frequency must be within

the tolerance specified in Table 3 on page 34.

NOTE: If the 121.5 MHz carrier frequency is within specified tolerance, the 243.0 MHz

frequency will also be within tolerance.

ELT ANTENNA

BNC CONNECTOR

(121.5/243.0 MHz)

TPS CONNECTOR

(406 MHz)

30 dB

ATTENUATOR

(if required)

MEASURING

DEVICE